Welcome to LookChem.com Sign In | Join Free

CAS No:123456789    This site contains about 108,618 DataSheet documents.

Position: Index > Categories > Semiconductors and Actives
CAS : 1299-86-1 ProductName : Aluminum carbide
1.
1.1
IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Product identifiers
Product name
Product Number
Brand
CAS-No.
:
:
:
:
Aluminum carbide
241873
1299-86-1
1.2
Relevant identified uses of the substance or mixture and uses advised against
Identified uses
:
Laboratory chemicals, Manufacture of substances
2.
2.1
2.2
HAZARDS IDENTIFICATION
Classification of the substance or mixture
Classification according to Regulation (EC) No 1272/2008 [EU-GHS/CLP]
Substances, which in contact with water, emit flammable gases (Category 2)
Skin irritation (Category 2)
Eye irritation (Category 2)
Specific target organ toxicity - single exposure (Category 3)
Classification according to EU Directives 67/548/EEC or 1999/45/EC
Contact with water liberates extremely flammable gases. Irritating to eyes, respiratory system and skin.
Label elements
Labelling according Regulation (EC) No 1272/2008 [CLP]
Pictogram
Signal word
Hazard statement(s)
H261
H315
H319
H335
Precautionary statement(s)
P231 + P232
P261
P305 + P351 + P338
Danger
In contact with water releases flammable gases.
Causes skin irritation.
Causes serious eye irritation.
May cause respiratory irritation.
Handle under inert gas. Protect from moisture.
Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray.
IF IN EYES: Rinse cautiously with water for several minutes. Remove
contact lenses, if present and easy to do. Continue rinsing.
P422
Supplemental Hazard
Store contents under inert gas.
none
Statements
According to European Directive 67/548/EEC as amended.
Hazard symbol(s)
R-phrase(s)
R15
R36/37/38
S-phrase(s)
S26
S43
Contact with water liberates extremely flammable gases.
Irritating to eyes, respiratory system and skin.
In case of contact with eyes, rinse immediately with plenty of water and
seek medical advice.
In case of fire, use fire-fighting equipment on basis class D.
2.3
3.
3.1
Other hazards - none
COMPOSITION/INFORMATION ON INGREDIENTS
Substances
Formula
Molecular Weight
Component
Tetraaluminium tricarbide
:
:
C3Al4
143,96 g/mol
Concentration
CAS-No.
EC-No.
1299-86-1
215-076-2
-
4.
4.1
4.2
4.3
5.
5.1
FIRST AID MEASURES
Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Consult a physician.
In case of eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Most important symptoms and effects, both acute and delayed
To the best of our knowledge, the chemical, physical, and toxicological properties have not been
thoroughly investigated.
Indication of any immediate medical attention and special treatment needed
no data available
FIREFIGHTING MEASURES
Extinguishing media
Suitable extinguishing media
Dry powder
5.2
5.3
5.4
6.
6.1
6.2
6.3
6.4
7.
7.1
7.2
7.3
8.
8.1
8.2
Special hazards arising from the substance or mixture
Carbon oxides, Aluminum oxide
Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
Further information
no data available
ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapors, mist or gas. Ensure
adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust.
Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Methods and materials for containment and cleaning up
Sweep up and shovel. Contain spillage, and then collect with an electrically protected vacuum cleaner or
by wet-brushing and place in container for disposal according to local regulations (see section 13). Do
not flush with water. Keep in suitable, closed containers for disposal.
Reference to other sections
For disposal see section 13.
HANDLING AND STORAGE
Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.Keep away from sources of ignition
- No smoking.
Conditions for safe storage, including any incompatibilities
Store in cool place. Keep container tightly closed in a dry and well-ventilated place.
Never allow product to get in contact with water during storage.
Moisture sensitive. Air sensitive. Store under inert gas.
Specific end uses
no data available
EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Components with workplace control parameters
Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and
at the end of workday.
Personal protective equipment
Eye/face protection
Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested
and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique
(without touching glove's outer surface) to avoid skin contact with this product. Dispose of
contaminated gloves after use in accordance with applicable laws and good laboratory practices.
Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and
the standard EN 374 derived from it.
Body Protection
impervious clothing, Flame retardant protective clothing, The type of protective equipment must be
selected according to the concentration and amount of the dangerous substance at the specific
workplace.
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle
respirator type N100 (US) or type P3 (EN 143) respirator cartridges as a backup to engineering
controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use
respirators and components tested and approved under appropriate government standards such
as NIOSH (US) or CEN (EU).
9.
9.1
PHYSICAL AND CHEMICAL PROPERTIES
Information on basic physical and chemical properties
a)
b)
c)
d)
e)
f)
g)
h)
Appearance
Odour
Odour Threshold
pH
Melting point/freezing
point
Initial boiling point and
boiling range
Flash point
Evaporation rate
Form: powder
Colour: beige
no data available
no data available
no data available
no data available
no data available
no data available
no data available
i)
Flammability (solid, gas) no data available
j)
k)
l)
Upper/lower
flammability or
explosive limits
Vapour pressure
Vapour density
no data available
no data available
no data available
m) Relative density
2,36 g/cm3 at 25 °C
n)
o)
p)
q)
r)
s)
t)
Water solubility
Partition coefficient: n-
octanol/water
Autoignition
temperature
Decomposition
temperature
Viscosity
Explosive properties
Oxidizing properties
no data available
no data available
no data available
no data available
no data available
no data available
no data available
9.2
10.
10.1
10.2
Other safety information
no data available
STABILITY AND REACTIVITY
Reactivity
no data available
Chemical stability
no data available
10.3
10.4
10.5
10.6
11.
11.1
Possibility of hazardous reactions
Reacts violently with water.
Conditions to avoid
Exposure to moisture.
Incompatible materials
acids, Keep away from water., Strong oxidizing agents
Hazardous decomposition products
Other decomposition products - no data available
TOXICOLOGICAL INFORMATION
Information on toxicological effects
Acute toxicity
no data available
Skin corrosion/irritation
Skin - Human - Skin irritation
Serious eye damage/eye irritation
Eyes - Human - Moderate eye irritation
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
IARC:
No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
no data available
Specific target organ toxicity - single exposure
Inhalation - May cause respiratory irritation.
Specific target organ toxicity - repeated exposure
no data available
Aspiration hazard
no data available
Potential health effects
Inhalation
Ingestion
Skin
Eyes
May be harmful if inhaled. Causes respiratory tract irritation.
May be harmful if swallowed.
May be harmful if absorbed through skin. Causes skin irritation.
Causes serious eye irritation.
Signs and Symptoms of Exposure
To the best of our knowledge, the chemical, physical, and toxicological properties have not been
thoroughly investigated.
Additional Information
RTECS: Not available
12.
12.1
12.2
ECOLOGICAL INFORMATION
Toxicity
no data available
Persistence and degradability
no data available
12.3
12.4
12.5
12.6
13.
13.1
14.
14.1
Bioaccumulative potential
no data available
Mobility in soil
no data available
Results of PBT and vPvB assessment
no data available
Other adverse effects
no data available
DISPOSAL CONSIDERATIONS
Waste treatment methods
Product
Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting
as this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal
company.
Contaminated packaging
Dispose of as unused product.
TRANSPORT INFORMATION
UN number
14.2
14.3
14.4
14.5
14.6
15.
ADR/RID: 1394
UN proper shipping name
ADR/RID:
ALUMINIUM CARBIDE
IMDG:
ALUMINIUM CARBIDE
IATA:
Aluminium carbide
Transport hazard class(es)
ADR/RID: 4.3
Packaging group
ADR/RID: II
Environmental hazards
ADR/RID: no
Special precautions for user
no data available
REGULATORY INFORMATION
IMDG: 1394
IMDG: 4.3
IMDG: II
IMDG Marine pollutant: no
IATA: 1394
IATA: 4.3
IATA: II
IATA: no
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
15.1
15.2
16.
Safety, health and environmental regulations/legislation specific for the substance or mixture
no data available
Chemical Safety Assessment
no data available
OTHER INFORMATION
Further information
The above information is believed to be correct but does not purport to be all inclusive and
shall be used only as a guide. The information this document is based on the resent state
of our knowledge and is applicable to the product with regard to appropriate safety precautions.
It does not represent any guarantee of the properties of the product. Lookchem shall not be
held liable for any damage resulting from handling or from contact with the above product.
See reverse side of invoice or packing slip for additional terms and conditions of sale.


Aluminum carbide   

Related Product

CAS No.1299-86-1 Aluminum carbide

Assay:98%Min Appearance:detailed see specifications Package:according to the clients requirement Storage:Store in dry, dark and ventilated place. Transportation:by ocean shipping or clients requirement Application:An important raw material and intermediate used in Organic Synthesis, Pharmaceuticals 

Min. Order:1Kilogram

Supplier:Dayang Chem (Hangzhou) Co.,Ltd. [ China (Mainland)]

CAS No.1299-86-1 High Purity aluminium carbide

Assay:99% Appearance:powder or liquid Package:according to customer requirements Storage:store in dry dark and ventilated place Transportation:By Sea/Air/Courier Application:It is an important raw material. 

Min. Order:10Gram

Supplier:Zibo Hangyu Biotechnology Development Co., Ltd [ China (Mainland)]

CAS No.1299-86-1 Aluminum carbide

Assay:99% Appearance:White powder Package:25KGS/Drum Storage:Room temperature Transportation:BY SEA Application:API锛孭harmaceutical intermediates 

Min. Order:1Gram

Supplier:HENAN NEW BLUE CHEMICAL CO.,LTD [ China (Mainland)]

CAS No.1299-86-1 Aluminium Carbide

Assay:98%, 99% Appearance:Refer to COA Package:According to clients' requirement Storage:Store in dry, cool and ventilated place Transportation:By sea or by air or by courier Application:As chemical reagents and etc. 

Min. Order:0

Supplier:Hangzhou Ocean Chemical Co., Ltd. [ China (Mainland)]

CAS No.1299-86-1 AluMinuM carbide

Assay:0.98 Appearance:Off white to slight yellow solid Package:1L 5L 10L 25L bottle Storage:Stored in shaded, cool and dry places Transportation:Handle with cares to avoid damaging the packages. Protect them from sunshine or rain. We can send by Fedex, by ship or by plane according to international rules. Application:pharma intermediate 

Min. Order:0

Supplier:Antimex Chemical Limied [ China (Mainland)]

CAS No.1299-86-1 Hot selling products CAS 1299-86-1 with fast delivery

Assay:99% Appearance:White powder Package: [Packaging]20mg, 50mg,100mg,1g,10g,100g,500g,1kg,25kg,according to customers' requirements Storage: should be stored in a well-closed container at low temperature, keep away from moisture, heat and light. Transportation:1. Express shipping, FedEx, UPS, DHL 2. Shipping 3. Air freight 4. Railway transportation, road transportation 

Min. Order:1Kilogram

Supplier:Zhuozhou Wenxi import and Export Co., Ltd [ China (Mainland)]